DC OEM Vacuum Pumps
OEM Air and Vacuum Pumps
GTek offers three different DC vacuum pump technologies to meet the various requirements of the OEM customer: Diaphragm, Linear-Motor Free Piston, and traditional Cup Seal. Each technology offers different operating characteristics and performance. Please consult your GTek representative to discuss the technology most suitable for your application. Typical lead time is 2-4 weeks, but varies based on demand.
Unit of Measure
Items |
DP0125-A1113-X1-0001 Diaphragm Pump, 2.5 LPM, -9.84 InHg to 4.35 PSI, 12VDC, Brush List Price QUOTE
|
DP0140-A1111-X1-0001 Diaphragm Pump, 4.0 LPM, -15.7 InHg to 7.25 PSI, 12VDC, Brush List Price QUOTE
|
DP0102H-A1150-X1-0001 Diaphragm Pump, 4 LPM, -15.0 InHg to 11.6 PSI, 12VDC, Brushless List Price QUOTE
|
DP0102-A1126-X1-0001 Diaphragm Pump, 5 LPM, -7.87 InHg to 6.52 PSI, 12VDC, Brushless List Price QUOTE
|
DP0102S-A1146-Y1-0001 Diaphragm Pump, 7 LPM, -7.87 InHg to 6.52 PSI, 24VDC, Brushless List Price QUOTE
|
|||||
Brands | N/A GTek Automation | |||||||||
Direct Current (DC) Rated Voltage | N/A 12 V | N/A 12 V | N/A 12 V | N/A 12 V | N/A 24 V | |||||
Direct Current (DC) Voltage Range | N/A | |||||||||
Current | N/A | |||||||||
Power | N/A | |||||||||
Noise per 30 Centimeter (cm) | N/A | |||||||||
Vacuum Operating Pressure | N/A | |||||||||
Open Flow Air Output | N/A | |||||||||
Outlet Outside Diameter (OD) | N/A | |||||||||
Weight per Each | N/A | |||||||||
Box Length | N/A 12 in | |||||||||
Box Width | N/A 9 in | |||||||||
Box Height | N/A 9 in | |||||||||
Attainable Vacuum | N/A -33.3 kPa-250 mmHg-333 mbar-9.84 inHg | N/A -53.3 kPa-400 mmHg-533 mbar-15.7 inHg | N/A -50.7 kPa-380 mmHg-507 mbar-15 inHg | N/A -26.7 kPa-200 mmHg-267 mbar-7.87 inHg | N/A -26.7 kPa-200 mmHg-267 mbar-7.87 inHg | |||||
Free Air Displacement1 | N/A 2.5 L/min0.088 ft³/min | N/A 4 L/min0.141 ft³/min | N/A 4 L/min0.141 ft³/min | N/A 5.0 L/min0.177 ft³/min | N/A 7 L/min0.247 ft³/min | |||||
Maximum Pressure | N/A 30 kPa0.3 kgf/cm²0.3 bar4.35 psig-9.8 inHg to 4.27 psi | N/A 50 kPa0.5 kgf/cm²0.5 bar7.25 psig | N/A 80 kPa0.8 kgf/cm²0.8 bar11.6 psig | N/A 45 kPa0.45 kgf/cm²0.45 bar6.52 psig | N/A 45 kPa0.45 kgf/cm²0.45 bar6.52 psig | |||||
Maximum Current | N/A 0.5 A | N/A 0.5 A | N/A 0.7 A | N/A 0.7 A | N/A 0.5 A | |||||
Duty Cycle | N/A Continuous | N/A Continuous | N/A | N/A | N/A | |||||
Life Expectancy | N/A 200 h | N/A 500 h | N/A 3,000 h | N/A 5,000 h | N/A 5,000 h | |||||
Straight Nipple Inlet and Outlet Outside Diameter (OD) | N/A 3 mm | N/A 5 mm | N/A | N/A 6 mm | N/A 6 mm | |||||
Coil Insulation Class | N/A E or its Equivalent (JETL) | |||||||||
Length | N/A 1.25 in32 mm | N/A 2-1/16 in52 mm | N/A 1-31/32 in50 mm | N/A 1-31/32 in50 mm | N/A 1-31/32 in50 mm | |||||
Width | N/A 1-9/32 in32.5 mm | N/A 1-7/16 in36 mm | N/A 1-3/16 in30 mm | N/A 1-3/16 in30 mm | N/A 1-3/16 in30 mm | |||||
Height | N/A | |||||||||
Gross Weight | N/A 0.18 lb0.08 kg | N/A 0.42 lb0.19 kg | N/A 0.55 lb0.25 kg | N/A 0.55 lb0.25 kg | N/A 0.55 lb0.25 kg | |||||
Rated Operating Time | N/A | N/A | N/A Continuous | N/A Continuous | N/A Continuous | |||||
Working Pressure Range | N/A | N/A | N/A -50.7 to 80 kPa-507 mbar to 0.8 bar -380 mmHg to 0.8 kg/cm² -15 inHg to 11.6 psig | N/A -26.7 to 45 kPa-267 mbar to 0.45 bar -200 mmHg to 0.45 kg/cm² -7.87 inHg to 6.52 psig | N/A -26.7 to 45 kPa-267 mbar to 0.45 bar -200 mmHg to 0.45 kg/cm² -7.87 inHg to 6.52 psig | |||||
Leadwire Length | N/A | N/A | N/A 15-3/4 in400 mm | N/A 15-3/4 in400 mm | N/A 15-3/4 in400 mm | |||||
Hose Barb Inlet Outside Diameter (OD) | N/A | |||||||||
Hose Barb Outlet Outside Diameter (OD) | N/A | |||||||||
Hose Nipple Inlet and Outlet Outside Diameter (OD) | N/A | N/A | N/A 6 mm | N/A | N/A | |||||
Ambient Temperature | N/A | |||||||||
Ambient Humidity | N/A | |||||||||
Fluid | N/A | |||||||||
Current (Mean Value) | N/A | |||||||||
Maximum Vacuum Pressure | N/A | |||||||||
Weight | N/A | |||||||||
Measure System | N/A EURO SI U.S.A | |||||||||
Motor Type | N/A | |||||||||
Connection Type | N/A | |||||||||
Driver Type | N/A | |||||||||
Applications | N/A Blood Pressure Tester Vacuum Tweezers | N/A Blood Pressure Tester Vacuum Tweezers | N/A Removal of micromachining chips Vacuum pick up and place devices for CD & DVD | N/A Endoscopes Removal of micromachining chips | N/A Endoscopes Removal of micromachining chips | |||||
Note | N/A Please read the page of "How to Use This Catalog" first for correct use of compressors and pumps. | |||||||||
|