Product Overview

* Click Here for Product Line Card.
* Click on Image to View Product Information.

1A. OEM Air Pumps.
* Applications Include Air Sampling, Analytical Devices, Blood Pressure Monitors, Clinical Diagnostics, Cosmetic Therapy, DNA Analysis, Drug Delivery, Micro Fluidics, Nebulizers, Portable Aspiration, Sterilization, Surgical Devices, Vacuum Hold Down, Vascular Therapy, Wound Aeration and Many Others.
* Voltage: 3 VDC, 6 VDC, 12 VDC, 24 VDC, 110 VAC, and 220 VAC.
* Pressure: Vacuum to 100 PSI.
* Open Flow Air Output: 0.04 CFM to 6.35 CFM (1 LPM to 180 LPM).
1B. Air Reservoir Cartridge.
* FDA Approved Polypropylene.
* Maximum Working Pressure: 125 PSI.
* Maximum Working Temperature: 100 Degrees F.
* Filtration: 50 Mesh Screens on Both Ends.
* Outside Diameter: 2″ (5″ L) and 2.5″ (6″ to 14″ L).
* Length: 5″, 6″, 8″, 10″, 12″, & 14″ Long.
* Port Size: 1/8″ (5″ L) and 1/4″ (6″ to 14″ L) Female NPT Threads.
1C. Solenoid Valves.
* Applications: For use on a Varity of Medical, Industrial and Appliance OEM Applications that Requires a Low Pressure/Low Cost Pneumatic Solenoid Valve.
* 2 Way: 6, 12 or 24 VDC, Normally Closed (N.C.), Amperage: 200 to 400 mA., Max. Pressure: 5.80 PSI (300 mmHg).
* 3 Way: 6, 12 or 24 VDC, Amperage: 370 to 400 mA, Max. Pressure: 5.00 PSI (260 mmHg).
2. OEM Water Pumps.
Applications Include Biochemistry Analyzer, Sterilizer, and Many Other Products in need of Liquid Pumping, Drainage, Filling and Circulating Liquids in Small Volumes.
* 12 VDC Versions.
* .08 to .40 LPM.
* Diaphragm Design.
* Brush Type DC Motors.
3. Panther Silent Oil Lubricated Air Compressor Systems.
* Silent Oil Lubricated Design.
* Noise Level: 30 db/(A) to 42 db/(A).
* Horsepower: 0.18 HP to 2.00 HP
* Voltage: 110 VAC to 220 VAC (50/60 Hz).
* Pressure: Up to 120 PSI.
* Open Flow Air Output: 0.70 CFM to 8.40 CFM (20 LPM to 240 LPM).
* Automation Air Filtration Kit Available for Oil and Water Removal.
4. Panther Oil Free Air Compressor Systems.
* Oil Free Design.
* Horsepower: 0.20 HP to 4.00 HP.
* Voltage: 110 VAC to 220 VAC (50/60 Hz).
* Pressure: Up to 120 PSI.
* Open Flow Air Output: 1.25 CFM to 25.00 CFM (35 LPM to 700 LPM).
* Metal Enclosure Option for -20 db/A Noise Reduction.
* Adsorption Air Dryer Available on Compressors with “E” Option.
* Air Filtration Kit Available for Water Removal for other Compressors.
5. Silver Rotary Screw Air Compressor Systems.
* Rotary Screw Design.
* Horsepower: 3.00 HP to 15.00 HP.
* Voltage: 220 VAC (50/60 Hz) to 208/240 or 460 VAC/60 Hz/3 Phase.
* Pressure: Up to 145 PSI.
* Open Flow Air Output: 10.6 CFM to 47.30 CFM (300 LPM to 1340 LPM).
* Noise Level: 59 to 67 db/A.
* Air Dryer Available on Compressors with “D” Option.
6. Automatic Air Filtration Kits For Air Compressors.
* Air Filters for Removal of Particulate Matter, Oil Mist & Condensation.
* Eliminates the Daily Maintenance of Manually Draining Fluids from Filters Bowls.
* All Filters have Automation Drains that are Plumbed to a Fluid Collection Bottle.
* Fluid within the Collection Bottle is Clearly Visible and is Drained as Needed.
* Designed for any Air Compressor with up to (4) Oil Lubricated Heads or Oil Free with up to 7 CFM Air Displacement.
* Larger Flow Air Filtration Kits are Available.
* For Best Results, Compressor should be Located at the Point of Use.
* Custom Air Filter Kits Available Upon Request.
7. Point of Use Air Filtration Kits. (Custom Air Filter Kits Available Upon Request)
AMBIENT AIR FILTER KIT:
* Includes: 1/4″ Tube Fittings, Lock Out Valve, Filter Regulator, Coalescing Filter, Ambient Water Separator w/Mounting Bracket, Fluid Collection Bottle with Mounting Bracket, and 10 ft of Tubing to Plumb the Air Filters to Fluid Collection Bottle.
-45 DEGREE DEW POINT DESICCANT AIR FILTER KIT:
* Includes: 1/4″ Tube Fittings, Pre-Coalescing Air Filter, Desiccant Dryer, Post-Coalescing Air Filter, Mounting Brackets and 10 feet of 1/4″ Tubing.

8. Refrigerated Air Dryers.
* Air Flow Rates: 10 – 175 SCFM.
* Environmentally Friendly Refrigerant.
* Plug & Play Design for Easy Installation and Operation (PRD10 – PRD125).
* Robust Timed Solenoid Drains Equals Improved Reliability (PRD15 – PRD175).
* Oversized Condensor to Operate in Ambient to 122 Degrees F (50 Degrees C).
* All Models Incorporate a Dewpoint Indicator.
* Extremely Compact Footprint.
9. Desiccant Air Dryers (Regenerative Type).
* Air Flow Rates: MiDAS: 3 – 20 SCFM & MIDIplus: 24 – 176 SCFM
* Provide Efficient Removal of Water Vapour from Compressed Air.
* Delivered Air Quality is in Accordance with All Editions of ISO8573-1, the International Standard for Compressed Air Quality.
* Pressure Dewpoint’s of -40 Degrees F (-40 Degrees C) and -94 Degrees F (-70 Degrees C).
* Lower Dewpoints Eliminate Corrosion and Inhibits Growth of Micro-Organism.
* Simple to Install and Easy to Maintain.
10. Nordson MEDICAL Quick Connect Couplers, Industrial Couplers, Air Hose and Misc Accessories.
* Nordson MEDICAL’s industry interchangeable quick couplings.
* Industrial Brass or Steel Couplers & Plugs.
* Nylon & Polyurethane Recoil Hoses.
* PVC Air Hoses.
* Manifolds & Manifold Kits
* Blow Guns,
* Brass Adapters.

11. TPC Pneumatic Components.
* Actuators.
* Directional Control Valves.
* Air Preparation Units.
* One Touch “Push In” Fittings, Tubing and Accessories.
* Vacuum Equipment.
* Accessories.
12. Fastest Rapid Sealing Tools for Leak Testing.
* Pressure and Leak Testing Tools.
* Vacuum to 10,000 PSI.
* External Sealing Range: 0.030″ to 5.040″ O.D.
* Internal Sealing Range: 0.310″ to 3.005″ I.D.
* External Thread Sizes: 1/8″ to 3″, -04 (7/16-20) to -16 (1 3/8-12).
* Internal Thread Sizes: 1/8″ to 4″, -03 (3/8-24) to -20 (1 5/8″-12).
* Various Thread Options Include: NPT/NPTF, BSP/BSPP/BSPT, Metric, SAE O-Ring, and SAE 37 & 45 Degree Flared Sizes.
13. TM Electronics Leak Testing Instruments.
LEAK AND LEAK/FLOW TESTERS.
* Pressure or Vacuum Decay Testing and Mass Flow or Occlusion Testing.
* Vacuum to 300 PSI.
* Resolution: 0.0001 PSI (0.01 mbar/sec).
PACKAGE TESTERS.
* Package Seal Strength and Package Integrity Testing.
* Seal Strength, Burst Test, Creep Test, Creep to Failure Test, Pressure Decay.
* 0 to 100 PSI.
* Resolution: 0.001 PSI (0.7 mbar).