ME Pneumatically Actuated Sealing Tool Seals External Smooth Tubes, Catheters & Luers.
Test Connection Tools
Pneumatic external sealing of medical devices in automated and semi-automated processes.
Typical Lead time is 1-2 weeks, but varies based on demand.
Typical Lead time is 1-2 weeks, but varies based on demand.
Unit of Measure
Items |
60MP0340 60 Series Connector, Seals Standard Luers, 750 PSI, 1/8" F NPT List Price QUOTE
|
MLB00101 Main Seal Pack, for Luer Connector 60M-P0340, 5 Pk, FDA Viton List Price QUOTE
|
ME0010030 ME Medical Connector, 0.015" - 0.030" O.D. Seal Range, 500 PSI, FDA Viton List Price QUOTE
|
ME0010050 ME Medical Connector, 0.030" - 0.050" O.D. Seal Range, 500 PSI, FDA Viton List Price QUOTE
|
ME001001 ME Medical Connector, 0.050" - 0.080" O.D. Seal Range, 500 PSI, FDA Viton List Price QUOTE
|
|||||
Description | N/A Typical Lead time is 1-2 weeks, but varies based on demand. | N/A Typical Lead time is 1-2 weeks, but varies based on demand. |
N/A
Pneumatic external sealing of medical devices in automated and semi-automated processes. Medical Series Connectors Typical Lead time is 1-2 weeks, but varies based on demand. |
N/A
Pneumatic external sealing of medical devices in automated and semi-automated processes. Medical Series Connectors Typical Lead time is 1-2 weeks, but varies based on demand. |
N/A
Pneumatic external sealing of medical devices in automated and semi-automated processes. Medical Series Connectors Typical Lead time is 1-2 weeks, but varies based on demand. |
|||||
Brands | N/A FasTest GTek Automation | |||||||||
Dimension A | N/A 2.92 in74.2 mm | N/A | N/A 1.72 in43.7 mm | N/A 1.72 in43.7 mm | N/A 1.72 in43.7 mm | |||||
Dimension B | N/A 0.88 in22.5 mm | N/A | N/A 0.84 in21.3 mm | N/A 0.84 in21.3 mm | N/A 0.84 in21.3 mm | |||||
Dimension C | N/A | N/A | N/A 0.63 in16.0 mm | N/A 0.63 in16.0 mm | N/A 0.63 in16.0 mm | |||||
Thread Size (Dimension D) | N/A | N/A | N/A 4-40 | N/A 4-40 | N/A 4-40 | |||||
Thread Type (Dimension D) | N/A | N/A | N/A Unified Coarse (UNC) | N/A Unified Coarse (UNC) | N/A Unified Coarse (UNC) | |||||
Dimension E | N/A | N/A | N/A 0.72 in18.3 mm | N/A 0.72 in18.3 mm | N/A 0.72 in18.3 mm | |||||
Minimum Insertion (Dimension M) | N/A | N/A | N/A 0.16 in4.1 mm | N/A 0.16 in4.1 mm | N/A 0.16 in4.1 mm | |||||
Pilot Port Thread Size (P) | N/A | N/A | N/A 10-32 | N/A 10-32 | N/A 10-32 | |||||
Pilot Port Thread Type (P) | N/A | N/A | N/A Unified Fine (UNF) | N/A Unified Fine (UNF) | N/A Unified Fine (UNF) | |||||
Outside Diameter (OD) Sealing Range | N/A | N/A | N/A 0.015 to 0.030 in0.38 to 0.80 mm | N/A 0.030 to 0.050 in0.80 to 1.30 mm | N/A 0.050 to 0.080 in1.30 to 2.00 mm | |||||
Termination Port Size (T) | N/A 1/8 in | N/A | N/A 1/8 in | N/A 1/8 in | N/A 1/8 in | |||||
Termination Port Type (T) | N/A Female National Pipe Thread (FNPT) | N/A | N/A Female National Pipe Thread (FNPT) | N/A Female National Pipe Thread (FNPT) | N/A Female National Pipe Thread (FNPT) | |||||
Connects To | N/A Luer | N/A | N/A Catheters Luers | N/A Catheters Luers | N/A Catheters Luers | |||||
Pressure Rating | N/A Vacuum to 51 barVacuum to 750 psi | N/A | N/A Vacuum to 34 barVacuum to 500 psi | N/A Vacuum to 34 barVacuum to 500 psi | N/A Vacuum to 34 barVacuum to 500 psi | |||||
Pilot Pressure | N/A | N/A | N/A 60 to 90 psi4.1 to 6.2 bar | N/A 60 to 90 psi4.1 to 6.2 bar | N/A 60 to 90 psi4.1 to 6.2 bar | |||||
Operating Temperature | N/A 0 to +200 ºF0 to +93 ºC | N/A | N/A 0 to +200 ºF-17 to 93 ºC | N/A 0 to +200 ºF-17 to 93 ºC | N/A 0 to +200 ºF-17 to 93 ºC | |||||
Operating Temperature for ICON™ | N/A | N/A | N/A 32 to 100 ºF0 to 38 ºC | N/A 32 to 100 ºF0 to 38 ºC | N/A 32 to 100 ºF0 to 38 ºC | |||||
Material | N/A | N/A | N/A Anodized Aluminum | N/A Anodized Aluminum | N/A Anodized Aluminum | |||||
Seal Material | N/A Food and Drug Administration (FDA) Approved Fluoroelastomer (FKM) | |||||||||
Note for Seal Material | N/A Additional seal material types available. | |||||||||
Pneumatic | N/A | N/A | N/A Pilot pressure applied to seals with no metal contact and uniform seal movement seals inside luer | N/A Pilot pressure applied to seals with no metal contact and uniform seal movement seals inside luer | N/A Pilot pressure applied to seals with no metal contact and uniform seal movement seals inside luer | |||||
ICON™ Technology | N/A | N/A | N/A Seal Life™ Sure Seal™ | N/A Seal Life™ Sure Seal™ | N/A Seal Life™ Sure Seal™ | |||||
ICON™ Intelligent Connection Technology | N/A | N/A | N/A FasTest's ICON™ adds sensing capabilities to our mechanical Sealing Connection Tools. ICON™ Tools include instant LED visual feedback and data output to improve sealing connection accuracy, maximize production efficiency, and optimize maintenance. | N/A FasTest's ICON™ adds sensing capabilities to our mechanical Sealing Connection Tools. ICON™ Tools include instant LED visual feedback and data output to improve sealing connection accuracy, maximize production efficiency, and optimize maintenance. | N/A FasTest's ICON™ adds sensing capabilities to our mechanical Sealing Connection Tools. ICON™ Tools include instant LED visual feedback and data output to improve sealing connection accuracy, maximize production efficiency, and optimize maintenance. | |||||
Sure Seal™ | N/A | N/A | N/A Instant LED feedback verifies a good connection prior to starting a test. | N/A Instant LED feedback verifies a good connection prior to starting a test. | N/A Instant LED feedback verifies a good connection prior to starting a test. | |||||
Seal Life™ | N/A | N/A | N/A Alert when the main seal is at end of life and must be replaced. | N/A Alert when the main seal is at end of life and must be replaced. | N/A Alert when the main seal is at end of life and must be replaced. | |||||
Programming Tool Features | N/A | N/A |
N/A
|
N/A
|
N/A
|
|||||
Features | N/A Fast Reliable Safe | N/A | N/A Reliable Safe |
N/A
All parts are washed in an aqueous solution utilizing ultrasonic agitation at a temperature of 140ºF. Components are then rinsed in a cascading rinse tank and dried using 99.999% pure nitrogen and assembled in a 100,000 ppm level controlled environment. Kryptox is the standard lubricant. White FDA Neoprene seal material is compliant to 21CFR177.2600. Optional material is a FDA listed fluorocarbon. Reliable |
N/A Fast Reliable | |||||
Additional Information |
N/A
|
N/A |
N/A
All parts are washed in an aqueous solution utilizing ultrasonic agitation at a temperature of 140ºF. Components are then rinsed in a cascading rinse tank and dried using 99.999% pure nitrogen and assembled in a 100,000 ppm level controlled environment. Kryptox is the standard lubricant. White FDA Neoprene seal material is compliant to 21CFR177.2600. Optional material is a FDA listed fluorocarbon. |
N/A
All parts are washed in an aqueous solution utilizing ultrasonic agitation at a temperature of 140ºF. Components are then rinsed in a cascading rinse tank and dried using 99.999% pure nitrogen and assembled in a 100,000 ppm level controlled environment. Kryptox is the standard lubricant. White FDA Neoprene seal material is compliant to 21CFR177.2600. Optional material is a FDA listed fluorocarbon. |
N/A
All parts are washed in an aqueous solution utilizing ultrasonic agitation at a temperature of 140ºF. Components are then rinsed in a cascading rinse tank and dried using 99.999% pure nitrogen and assembled in a 100,000 ppm level controlled environment. Kryptox is the standard lubricant. White FDA Neoprene seal material is compliant to 21CFR177.2600. Optional material is a FDA listed fluorocarbon. |
|||||
Note |
N/A
All parts are washed in an aqueous solution utilizing ultrasonic agitation at a temperature of 140 ºF. Components are then rinsed in a cascading rinse tank and dried using 99.999% pure nitrogen and assembled in a 100,000 ppm level controlled environment. Kryptox is the standard lubricant. Components are double bagged for shipping integrity. Body sold separately, select seal set for the base connector. |
N/A |
N/A
Additional seal material types available. Body sold separately, select seal set for the base connector. |
N/A
Additional seal material types available. Body sold separately, select seal set for the base connector. |
N/A
Additional seal material types available. Body sold separately, select seal set for the base connector. |
|||||
Connection Type | N/A Sleeve Actuated | N/A | N/A | N/A | N/A | |||||
Material of Construction | N/A Anodized Aluminum Stainless Steel | N/A | N/A | N/A | N/A | |||||
Sleeve Actuated | N/A Easy, ergonomic sleeve action eliminates repetitive twisting and turning - push to connect, pull to release | N/A | N/A | N/A | N/A | |||||
|